+91 96999 88732
+91 92848 78168

Products

Static Pass Box

Static Pass Box

Static Pass Box

Static Pass Box

Static Pass Box

Pass box is one of the clean room systems, which is used to transfer materials from one side to other side through controlled environment in order to avoid airborne cross contamination. As the name states itself, the primary and only work of a pass box is to pass material from one side to other without raising contamination concern and if any particulate matter presents on the material surface, it swipes away during the operation. Interlocking door mechanism is the prime feature of a pass box, when door at one side is open the door at other side remains closed. It is popular with other names such as clean room pass through, clean transfer window and transfer hatch; in addition, it is widely used in microbiology laboratories in food, pharmaceutical and chemical industries.

Specifications

  • Door: SS 304, SS 316, SS 316L, double-walled door construction with flush glass view panels with SS handles and SS hinges.
  • Interlocking: Electro-magnetic Interlocking type door arrangement to ensure that only one side door can be opened at any given,time.
  • Door Indications: Indicators one side for the door open condition.
  • Door Release: The door release switch is on either side.
    SS COVING: Internal covings for easy

Optional accessories

  • UV light with an hour meter used for bacteria/virus killing & an interlocking arrangement to turn off UV light if either side door opens. 
  • Support stand for mounting of the passbox
  • Flange for sealing the gap between the passbox and the clean room wall
  • Electro –magnetic /mechanical Interlocking
  • Floor mounted construction with three side wall structure & Door Drop seal
  • Provision for ventilation with perforated grills
  • Flame proof fitting

Documentation

All necessary documents will be provided as per the latest prevailing standard.

Static Pass Box

Static Pass Box

Static Pass Box

Static Pass Box

Dynamic Pass Box

A dynamic pass box is a cubicle box which has got interlocked doors located on both sides. This protects the controlled environment from being polluted while the transfer of  material is taking place inside. Pass box is used to transfer the material from lower cleanliness area to higher cleanliness area or vice-versa in the classified area and also known as the hatch. Pass box works as a barrier between two cleanliness level areas. Static pass boxes are used to transfer materials between two rooms of equal cleanliness levels and are designed for minimal  personnel movement while  dynamic pass boxes are used to transfer materials from uncontrolled to controlled  environments. Dynamic pass box  works like an airlock or laminar air flow unit.

Static Pass Box

Static Pass Box

Static Pass Box

Static Pass Box

Vertical Laminar Air Flow Unit (VLAF)

Laminar airflow (VLAF) refers to the flow within an air distribution system that follows the principle of laminar flow of air. When gas molecules travel in straight, parallel layers without intersecting or mixing with each other, laminar conditions are formed. In an enclosed space, the uniformity in
velocity and direction due to laminar airflow provides the opportunity for creating an efficient circulation system.
The circulation of the filtered air within a system is key to keeping a clean and contamination-free environment. 

Specifications

  • Hepa Filter: Imported mini pleate HEPA Filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% for 0.3 micron.
  • PRE-Filter: Pre –filter are made from non are made from non-woven synthetic with HDPE mesh, conforming to EU6 grade, with an efficiency rating better than 95% down to 5 microns.
  • Motor blower assembly: Motor blower designed of statically and dynamically balanced for the supply of sufficient capacity and static pressure to take care of the air flow requirement for entire life of HEPA.
  • Pressure gauge: magnehelic gauge (0-25mm:1 Nos.)to monitor pressure drop across HEPA filter.
  • Lighting: Fluorescent light (250 lux)at work surface
  • ON/OFF switches: Keypad ON/OFF Switches for motor & Lights.
  • Switch socket: 6/15 amp Single –phase switch socket use for external equipment
  • Control panel: Electrical control panel mounted in unit
  • Work table: SS work table with due reinforcement
  • DOP port: DOP test port at upstream of HEPA filter integrity test. (with PAO Solution)
  • Side panel: Toughened glass /SS sheet /Acrylic Sheet Side panel screens for maximum visibility
  • Electrical supply: 230V AC 3-Ø 50 HZ/415V AC 3- Ø 50 HZ
  • Noise level: Less than 67 dB on scale “A” when Ambient is not greater than 55 dB on scale “A”
  • Vibration level: minimum
  • Air flow: Vertical

Optional accessories

  • Anti-static PVC strip curtains
  • Suspension rod Option available in MS and SS
  • UV Light with hour meter

Documentation

All necessary documents will be provided as per the latest prevailing standard.

“Where Innovation Meets Compliance — Your Partner in Clean Air Technology”​